dc.description | Antecedentes: en los pacientes críticos es fundamental monitorizar la oxigenación tisular, ya que se requiere para guiar la terapéutica y calcular los puntajes de escalas pronosticas. A pesar de esto, los parámetros empleados rutinariamente con éste propósito como del DO2 y el VO2 así como SOFA, no siempre brindan información inmediata, debido a que su realización implica dificultades técnicas y tecnológicas especiales. Se ha indicado que el índice arterio-venoso de la Presión de dióxido de carbono (Iv-aPCO2) es un método que puede realizarse como prueba de cabecera en aquellos pacientes críticos con catéter en arteria pulmonar, proporcionando una aproximación al nivel de oxigenación tisular, sin embargo. Su validez ha sido cuestionada. Objetivo: Se realizó un estudio para determinar si la medición del Iv-aPCO2 era un predictor temprano de hipoxia tisular en pacientes en estado crítico. Metodología: En la Unidad de Cuidados Intensivos del hospital Teodoro Maldonado en Guayaquil – Ecuador se realizó un estudio transversal en el que se incluyeron 43 casos consecutivos de pacientes críticos que a los cuales se les midieron y calcularon varios parámetros que indican el nivel de oxigenación tisular. Para establecer el grado de correlación se empleó el índice de Pearson y se consideró significativos valores de P < 0.05. Resultados: los resultados mostraron que la mayoría de los parámetros de valoración de pacientes críticos se encontraban alterados reflejando la condición del paciente (IC, IVS, IRVS, EO2, CqO2, CvO2, PAM, VU, SvO2, PaCO2, PvCO2, Hb SO2, PaO2). Tampoco existió correlación entre los valores de VO2 (R= 0,24; P 0,128), DO2 (R= 0,16; P 0,308) y SOFA (R,113; P 0,472) con los valores de Iv-aPCO2. Conclusión: IvaPCO2 no puede reemplazar a los valores tradicionales de evaluación oxigenación tisular en paciente críticos, pero debe ser utilizado como parte general de la evaluación ya que aporta información valiosa y complementaria | es |
dc.description.abstract | Background: Monitoring of tissue oxygenation is essential for critically ill patients, since this value is required to guide therapy and to calculate prognostic scales scores. In spite of this, the parameters routinely used for this purpose such as DO2 and VO2 as well as the SOFA prognostic score can not always provide immediate information and are not readily available because their implementation implies Specials technical and technological difficulties, which are not always available. It has been suggested that the arterio-venous index of the Carbon dioxide Pressure (Iv-aPCO2) is a method that can be performed as a bedside test, especially in those critical patients with a pulmonary artery catheter and who provides at least theoretically an approximation to the level of tissue oxygenation, however. This validity has been questioned. Objective: A study was conducted to determine if the measurement of Iv-aPCO2 was an early predictor of tissue hypoxia in critically ill patients. Methodology: In the Teodoro Maldonado Hospital’s - Intensive Care Unit from Guayaquil, Ecuador, a cross-section study was carried out in which 43 consecutive cases of critical patients were included, which were measured and calculated several parameters that indicate the level of tissue oxygenation. Pearson's index was used to establish the degree of correlation and values of P <0.05 were considered significant. Results: The results showed that, in a logical manner, most of the critical patient assessment parameters were altered reflecting the patient's condition (IC, IVS, IRVS, EO2, CqO2, CvO2, PAM, VU, SvO2, PaCO2, PvCO2, Hb SO2, PaO2). There was also no correlation between the values of VO2 (R = 0.24, P 0.128), DO2 (R = 0.16, P 0.308) and SOFA (R, 113, P 0.472) with Iv-aPCO2 values. Conclusion: IvaPCO2 cannot replace the traditional values of tissue oxygenation evaluation in critical patients, but it should be used as a general part of the evaluation because it provides valuable and complementary information | es |
dc.language.iso | spa | es |
dc.rights | openAccess | es |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | es |
dc.subject | : Paciente Crítico | es |
dc.subject | . Oxigenación Tisular | es |
dc.subject | Choque. | es |
dc.subject | Diagnóstico | es |
dc.title | VALOR DEL ÍNDICE V-A DE PCO2 COMO PREDICTOR TEMPRANO DE HIPOXIA TISULAR EN PACIENTE CRÍTICO | es |
dc.type | masterThesis | es |
Aparece en las colecciones: | ESPECIALIDAD EN MEDICINA CRÍTICA |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
Valor Del Índice V-A De PCO2 Como Predictor Temprano De Hipoxia Tisular En Paciente Crítico.pdf | 718.93 kB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.